Application Area |
|
Measurement Range | APT3100L-6 0 ... 0,34bar / 0...7 bar APT3100L-7 0 ... 1 bar / 0 ... 20 bar APT3200L-8 0 ... 3 bar / 0 ... 70 bar |
Temperature | -40 ... +125 °C ( Opt.400°C) |
Connection Measurement | 2" .or 3" |
Connection Norm | Flange ( ANSI,JIS ASME ) |
Cable Union | 1/2" NPT , M20x1,5 , Ex Gland |
Wet Parts | Diaphragm AISI316 L, Hastelloy C ,Tantalum Trunk AISI316SS |
Capilary Pipe Length | 0 ... 12 m ( Opt. Depends On The Customer's Request ) |
Connection Parts | AISI316 L, Hastelloy C , Tantalum |
Preservation/Housing | Epoxy Coated Aluminium / Stainless Steel |
Analog Output Signal | 4...20 mA |
Digital Communication | HART |
Communication Protocol | Opt.Modbus,Profibus PA , Foundation Fieldbus |
Supply Voltage | 10 ... 45 VDC |
Protection Class | IP67 |
Approval | Ex d II C T6 , Ex ia II C T6 |
Precision | % 0,075 Std. (Opt. %0,05 ) |
Stability | 0.125% URL/3 Years |
Indicator Options | Compact , Remote ( Seperate ) |
Indicator Parameters | All Engineering Units , Percentage Value , Current Value ( Only one or all of them by rotating can be watched ) |
Quality Certificates | IS09001 / CE |